However it is still used to auto size buffers and because of this it should never be set below 10. When using the Manual Stop, the Total Scans to Acquire is ignored for the purpose of counting scans. Manual instructs the acquisition to Stop when the Program's Stop button is pressed. Immediate instructs the acquisiton to start when LabVIEW is started. The StartType and StopType fields commands the driver to begin and end in a specific way. Below they are set to Immediate and Manual. The Total Scans to Acquire is used to size a working buffer in the driver and instructs the example as to how many samples to acquire before stopping. The term Scan is used to indicate one reading from each enabled channel. For example, "DaqBoard2k0". The PersonalDaq/3000 series does not use Daq Configuration.īelow I have circled some of the fields. The ScanRate is the sample rate which is number of samples per second. If you have a DaqBook or DaqBoard and are looking at the DaqBook 2001 Analog Input Example, make sure the Device Name is the same name that is found in the Daq Configuration Windows Control Panel utility. If you have another IOtech device such as the PersonalDaq/3005 then change the name to PersonalDaq3005. The driver software locates the device using the Device Name so if it wrong the program will not run. Open the Personal Daq 3001 Analog Input Example VI.Īt this time take note of the Device Name property. This folder contains examples for DaqBoards, DaqBooks, DaqLabs, DaqScan and the PersonalDaq/3000 series. As you can see these are located under the Daq Device Examples folder. The following image shows the path to PersonalDaq/3001 examples. Instead it is suggested to start with examples specific to your device. This folder contains support for IOtech devices and browsing through it often leads to confusion. Once installed there will exist a DaqIO LabVIEW Support folder typically located under Program Files. Select the folder that best reflects your device then choose LabViewDaqCom2Setup.exe At the bottom of the page you find IOtech Downloads. If you are in need of the installation, access the TechSupport->Software/Driver Downloads. To begin the IOtech LabVIEW Support installation installs not only the VI support but also the drivers for IOtech devices. This is the first article in a series that describes the basics of the IOtech LabVIEW Support.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |